AC Resistive Load Banks
Minimum Order Quantity | 1 Unit |
Brand | National Resistors |
Material | Fe-Cr-Al (SS-406),SS 304 |
Power Rating | 1 kW to 3000 kW |
Hardware | Zinc plated |
Phase | Three Phase |
Frame Material | Galvanized Steel,MS (CRCA) |
Capacity | Customised |
Frequency | 50 Hz/60Hz |
IP Grade | IP 20 |
Power | Customised |
Temperature | 375 C |
Voltage | 414 V-600 V |
Usage/Application | For DG Testing,UPS Testing,Transformer Testing,AS Dummy Load |
Our firm is dedicatedly engaged in manufacturing, supplying and exporting AC Resistive Load Banks Unit. These resistors consist of Copper Nickel alloy wire grid elements that are supported on MS tie rods. Offered resistors are designed and developed so as to provide natural and rapid cooling of resistors bank. Moreover, these resistors are convenient to install and are designed to support various panels in different industries worldwide. Valued patrons can avail Battery Discharge Resistors Unit from us at most affordable prices, ensuring safe transit.
Features and Advantages:
- Discharge cycle tests help the users to:
- Checking the initial battery performances.
- Avoid deterioration of battery systems due to early detection defective cells
- During emergencies guarantee smooth operation of back up systems
- Suitable for improving overall health and life of battery systems.
Constant Current and Rate of Discharge: D.C contractors / Circuit breakers or knife edge switches are used for switching depending on clients preference. The Rate of Discharge can be accurately controlled and monitored in this system which is can be accurately controlled and monitored in this system which has the distinct advantage over other conventional methods of Discharge.
Information Needed For Design:
- Maximum voltage to minimum voltage of battery required to be discharged.
- Current steps required for each step of discharge voltage.
- The material of resistor element.
- Temperature rise allowed.
Ratings: AC & DC Load Banks are manufactured as per customers requirement in various ratings ranging from 1 KW to 3000 KW. (Optional) High-Temperature Limit Thermostat for resistance elements, Thermal overload for each fan and overflow switches are provided.
Construction:
Hot dip galvanized frames fitted with galvanized steel if required otherwise heat resistance aluminum paints are used. All hardware is zinc plated. Stainless Steel hardware is used if required. Frames can be custom made also.
Disconnect Panels/Load Break Switch Panel
Minimum Order Quantity | 1 Unit Onwards |
Application | Neutral Grounding of Transformer |
IP Rating | IP55 |
Material | Aluminium |
Warranty | 12 months from commissioning/18 months from dispatch |
Automatic Grade | Automatic |
Disconnect Panels/LBS Panel are offered with requisite mechanical and electrical interlocking. The disconnect panels are ideal for connecting and disconnecting of AC current between on and off conditions. The panels provide a compact solution for power circuit protection. Disconnect Panels come with factory-set disconnect voltages and these can be manually adjusted in the field, to suffice requirements.
The disconnect panels are designed to protect assets from damage during Undervoltage or overcurrent. This can be incorporated into any equipment that is needed to be protected. At times of emergency, this system shutdowns the equipment. If you also have substantially invested in machinery and equipment, then ensure their complete safety, and assure long-term reliability by disconnect panels.
Formed Stainless Steel Neutral Grounding Resistor
Thickness | 0.4-1.0 mm |
Zinc Coating | 60-140 g/sq.m |
Material | Stainless Steel |
With the assistance of our team of professionals, we are engaged in providing an assorted range of Formed Steel Grid. Steel grid offered by us is manufactured employing excellent quality steel in line with international market standards. Provided steel grid is mainly used in electrical circuits as the spacer between grid element. The offered steel grid is provided in various specifications and can be customized also as per the requirements of the clients. This Formed Steel Grid is strictly tested on several quality parameters prior to dispatch.
The efficient features include:
- Galvanized M.S. washers will be used as the spacer between grid element and the same is insulated from grids by using mica washers.
- Temperature coefficient of resistance is 0.15% / c for AISI-410 0.094%/ c for AISI-304.
- The connection between adjacent grid is done by Arc Welding.
- Grids are formed of AISI - 304/AISI - 410 Stainless Steel materials.
Features:
- Grids are formed of AISI - 304/AISI - 410 Stainless Steel material
- Temperature coefficient of resistance is 0.15% / c for AISI-410 & 0.094%/ c for AISI-304.
- The connection between adjacent grid is done by Arc Welding.
- Galvanized M.S. washers will be used as the spacer between grid element and the same is insulated from grids by using mica washers.
Specifications:
- IPSS-1-10-002-82 with amendment no.1 and BS 587 for starting/speed control resistor.
- IS 2147 & IS 12063 of 1987 for the degree of protection for an enclosure.
- IS 5 for paint shade.
- Any other standard as required can also be followed.
Load Banks For Generator Testing
Power | 1KW / 2KW / 5 KW / 10KW |
Voltage | 440V AC |
Material | Stainless Steel |
Usage | Electrical industry |
Our esteemed clients are mesmerized by our offerings in the domain of manufacturing and wholesaling a qualitative array of Load Banks for Generator Testing. This range is demanded for its smooth functioning, user friendliness and cost effectiveness. Power to take control of all load testing requirements. Moreover, these are manufactured under the supervision of our expert team in order to ensure a genuine range to the clients.
Feature:
Optimum performance
High efficiency
Reliable
Sturdy design
We deals in Gulf Countries like Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates and Middle East Countries.
Load Banks For Industrial Automation
Power Ratings | Up To 1000 Kw |
Primary Voltage | 440V AC 3Phase/ 220V AC Single phase/ 220V DC |
Frequency | 50-60 Hz |
Current | 15 A |
We are engaged in offering of Load Banks for Industrial Automation. Known for its compact structure and high level of efficiency, Load Banks are highly appreciated in the market.
What is Load Bank:
- Load banks are compact units that are coupled to the output of your power generation system such as diesel generators, gas turbines or UPS and battery systems
- Load banks are dummy loads, designed to simulate the plant load and prove the design, performance and the capacity of the system, without interruption to the normal running of your plant
- Enclosed in the cabinet with Steps provided for loading, meters provided for each phase & terminations brought out on bakelite strip
Load Banks For UPS
Voltage Primary | 440V AC |
Power | 1KW / 2KW / 5 KW / 10KW |
Usage | Electrical industry |
Material | Stainless Steel |
Our esteemed clients are mesmerized by our offerings in the domain of manufacturing and wholesaling a qualitative array of Load Banks for UPS. This range is demanded for its smooth functioning, user friendliness and cost effectiveness. Moreover, these are manufactured under the supervision of our expert team in order to ensure a genuine range to the clients. The load bank is used in UPS system testing, testing.
Feature:
Optimum performance
High efficiency
Reliable
Sturdy design
We deals in Gulf Countries like Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates and Middle East Countrie.
Load Banks For UPS
We are engaged in offering best quality of Load Break Switch Panel. This Load Break Switch Panel is offered by us to customers at market leading prices. Further, the offered Load Break Switch Panel is extensively used in applications like transformer switching and in many others. One can avail these products from us in bulk.
Features:
- Compact design
- Cost effective prices
- Highly efficient
Load Break Switch Panel
We are engaged in offering best quality of Load Break Switch Panel. This Load Break Switch Panel is offered by us to customers at market leading prices. Further, the offered Load Break Switch Panel is extensively used in applications like transformer switching and in many others. One can avail these products from us in bulk.
Features:
- Compact design
- Cost effective prices
- Highly efficient
Neutral Earthing (NER)/ Grounding Resistor (NGR)
Minimum Order Quantity | 1 Unit Onwards |
Tolerance | +/-10% |
Voltage | 415 V-33KV |
Frequency | 50-60 Hz |
Power | Up To MW |
Brand | National Resistors |
Material | SS 304, SS 410, SS 406,SS 430, Cast Iron, Fe- Cr-Al 406 |
Condition | New |
Size | Customised |
Usage/Application | System Grounding of Transformer and DG Sets |
We are offering Neutral Earthing Resistors (NER)/Neutral Grounding Resistor (NGR) to our clients. Since establishment, we have been dealing in transformer neutral earthing designed to provide the high-end performance to the clients. Our solutions are developed from the optimum grade raw materials to ensure maximum performance and efficacy. We provide the clients with a vast collection of products designed in different sizes and specifications to match up with the exact needs of the clients. Our solutions can also be tailored as per the exact needs of the clients within the stipulated time frame. The range, offered by us, is highly demanded in the market for maximum durability, low maintenance, and reduced continuation cost. Robust designs and anti abrasive nature ensures long lasting life. The product line is available at very competitive prices to provide the clients with the best within their budget.Other Details:Resistance value pre-determined to operate fault-clearing relays and to prevent damages.The system is designed as per to current and time ratings and compatible with the protection switchgear.The resistance value is precise and determined and remains constant throughout life.Made from tough steel grids of a high-quality iron-chrome-aluminum.Non-corroding and offer good stability.Mica and ceramic insulators.The resistor in fully protected and ventilated steel enclosures.
Neutral Grounding Resistors
Resistance | 50 ohm |
Material | Wire-wound Resistor |
Technology | Metal Alloy |
Usage | Electrical industry |
Known for its smooth functioning and wide application areas, our range of Neutral Grounding Resistors is extensively demanded and availed by our clients at the most reasonable and competitive prices. Besides, our expert team give special care to the quality aspects of our offered products.
Feature:
Robust construction
Compact design
Durable
Product detail:
Rated Voltage : For neutral grounding or earthing resistor rated voltage means line- to neutral voltage i.e. System Voltage divided by root 3 i.e. 1.732
Rated Current : Means Initial current that will flow through resistor when it is cold. Normally Full load current value is same as Rated current
Time Rating : It is length of time for which NGR must tolerate rated voltage
Short Time Rating : Normally it is 10 sec. or 30 sec. or 60 sec. depending on design parameters of protection system
Continuous Rating : It is normally 10 % of full load current for healthy system neutral grounding resistor to be designed for continuous rating of 5 % to 10 % of full load current
Temperature Rise Allowed: Normally Temperature rise is restricted to 375 deg.c. above ambient temperature as per BS-587
Cabling or termination : Suitable arrangement and clearance is provided for termination of cable, flats or bus duct as per requirement with removable gland plate
Construction: NGR include resistor assembly, plus required insulators, internal connections and hardware etc
Material of Resistance Element : We offer resistor elements made from any stainless steel or Cu-Ni or Ni-Cr or any other resistance material as per requirement. Normally formed stainless steel element are best and economical for NGRS
We deals in Gulf Countries like Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates and Middle East Countrie.
Earthing Resistors
Application | Neutral to Earth Grounding |
Voltage Type | AC |
Material | Wire-wound Resistor |
Size | Customized |
Earthing Resistors that is manufactured and designed by us comply with the international quality standards. For that matter, our team make use of ultramodern machineries available at our base. Besides, our range has been priced very competitively and requires less maintenance.
Feature:
Optimum performance
High efficiency
Sturdy design
Product detail:-
Rated Current : Means Initial current that will flow through resistor when it is cold
Time Rating : It is length of time for which NGR must tolerate rated voltage.
Short Time Rating : Normally it is 10 sec. or 30 sec. or 60 sec. depending on design parameters of protection system
Rated Voltage : For neutral grounding / earthing resistor rated voltage means line- to neutral voltage i.e. System Voltage divided by root 3 i.e. 1.732
Material of Resistance Element : We offer resistor elements made from any stainless steel or FeCrAl or Cu-Ni or Ni-Cr or any other resistance material as per requirement. Normally formed stainless steel element are best and economical for NGRS
Continuous Rating : It is normally 10 % of full load current for healthy system neutral grounding resistor to be designed for continuous rating of 5 % to 10 % of full load current (if required)
Temperature Rise Allowed: Normally Temperature rise is restricted to 375 deg.c. above ambient temperature as per BS-587
Construction: NGR include resistor assembly, plus required insulators, internal connections and hardware etc
Cabling / Termination : Suitable arrangement and clearance is provided for termination of cable, flats or bus duct as per requirement with removable gland plate
We deals in Gulf Countries like Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates and Middle East Countrie.
Grounding Resistors
Material | Wire-wound Resistor |
Usage | Electrical industry |
Resistance | 50 ohm |
Power | 33 KV |
Features:
- Suitable for printed circuit board
- Completely insulated resistor
- Products diversity
We deals in Gulf Countries like Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates and Middle East Countries
Load Bank
Capacity | 1 kW To 500 kW |
Temperature | 100 degreeC |
Dielectric Strength | 2500 VAC |
Usage | Electrical industry |
Our esteemed clients are mesmerized by our offerings in the domain of manufacturing and wholesaling a qualitative array of Load Banks. This range is demanded for its smooth functioning, user friendliness and cost effectiveness. Moreover, these are manufactured under the supervision of our expert team in order to ensure a genuine range to the clients.
Feature:
Optimum performance
High efficiency
Reliable
Sturdy design
- Zinc plated hardware
We deals in Gulf Countries like Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates and Middle East Countrie.
Load Banks For UPS
Voltage Primary | 440V AC |
Power | 1KW / 2KW / 5 KW / 10KW |
Usage | Electrical industry |
Material | Stainless Steel |
Our esteemed clients are mesmerized by our offerings in the domain of manufacturing and wholesaling a qualitative array of Load Banks for UPS. This range is demanded for its smooth functioning, user friendliness and cost effectiveness. Moreover, these are manufactured under the supervision of our expert team in order to ensure a genuine range to the clients. The load bank is used in UPS system testing, testing.
Feature:
Optimum performance
High efficiency
Reliable
Sturdy design
We deals in Gulf Countries like Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates and Middle East Countrie.
NGT Loading Resistor
Material | SS |
Brand | National Resistors |
Max. Current Rating | 15 A |
Voltage | 33 Kv |
Power | 55 W |
Frequency | 50 Hz |
Number Of wires | 4 |
The Metering cubicle shall be totally enclosed and shall be provided with two no. the hinged door made of MS sheet which shall rest on the collar along the four sides of cubicle so that the doors remain flushed with the body of the cubicle to the safety and performance standards.
Speed Control Resistor/Starting Resisitor/Rotor Resistor Panel
Material | Stainless Steel |
Brand | National Resistors |
Usage/Application | Industrial |
Tolerance | +/-10% |
Power | Electric |
Minimum Order Quantity | 1 Unit Onwards |
Material | Stainless Steel -304 , 406 |
Power | Customised |
Rated Voltage | Customised |
Tolerance | +/-10% |
Condition | New |
Brand | National Resistors |
We are offering Speed Control Resistor to our clients. For starting/Speed Control of AC or DC Motors, resistors are manufactured as per customers requirement at specified starting torque or for limiting initial inrush current to an acceptable value. Mainly these are used for cranes. The rating can be 2 minutes, 5 minutes, 10 minutes, continuous or intermittent. The material of resistor is normally Stainless steel AISI-304, AISI -410 or AISI 430 or FeCrAl-AISI-406.
Standards Followed:
- IPSS-1-10-002-82 with amendment no.1 and BS 587 for starting/speed control resistor
- IS 2147 & IS 12063 of 1987 for the degree of protection for an enclosure
- IS 5 for paint shade
- Any other standard as required can also be followed
Tests:
Routine Tests: Following tests Will Be Conducted
Visual and Dimensional:
- Insulation resistance value measurement by using 500V megger before and after the dielectric test
- Resistance value measurement with ± 10 % tolerance
- H.V. Test of twice the rated voltage +1000 volts for voltage class below 660 volts
Type Tests: Temperature rise test i.e., Heat run test, if required, will be conducted by passing equivalent/rated current for rated/equivalent time keeping IT Constant through a part of Resistor.
Starting/Speed Control resistor Product Information:
- Rotor volts at the standstill
- Rotor Current at full load
- Duty rating (Time on/off No. of Cycles)
- Starting Torque in the percentage of full load Torque
- The material of Resistor
- No. of steps/sections and its resistance values per phase
- Type of enclosure (Protection Class as per IS-12063)
- Temperature rise allowed
- Whether terminals should be brought down at one place
- Details of atmospheric conditions at the site
For Buffer resistors:
- Rotor volts at the standstill
- Rotor Current at full load
- Percentage (%) of slip required
33 KV Electrical Isolator
Output Voltage | 33 kV |
Condition | New |
Break | Single/Double |
Current | Up To 1500 Amp |
We offer 33 kV Electrical Isolator and these resistors are widely used isolating high-voltage equipment. The isolator ensures the safe functioning of the equipment. The isolators are popular amongst industrial buyers for their uninterrupted performance and ability to withstand high electrical disturbances. The isolators can be custom made to meet the requirement of Horizontal/vertical type, single break, double break, tilting type, rotating type, single/double break consisting of hot-dip galvanized iron base, etc.
Battery Discharge Resistor
System Rated Voltage | 280KV |
Weight | 250 kg |
Material | Stainless Steel |
Usage | Electrical industry |
Owing to our long time involvement in the domain of manufacturing and supplying a wide range of Battery Discharge Resistor that is of excellent quality. Respected clients can avail our manufactured resistors as per their preferences and requirements by spending only a reasonable amount.
Feature:
Quality approved
Robust size
Durable standard
Avoid deterioration of battery system due to early detection defective cells
Check initial battery performance against manufactures specifications
Improve overall health and life of battery system
Maximum voltage to minimum voltage of battery required to be discharged
Guarantee smooth operation of back up system during emergencies
Material of resistor element
Temperature rise allowed
We deals in Gulf Countries like Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates and Middle East Countries.
DC Load Banks/Battery Discharge Resistor
Minimum Order Quantity | 1 Unit Onwards |
Power | Customised |
Voltage | 10 Volt DC-600 Volt DC |
Usage/Application | For Battery Discharging |
Temperature | 375 Degree Celsius |
IP Grade | IP 20 |
Brand | National Resistors |
Material | Fe-Cr-Al (SS-406), SS 304 |
We are offering Load Banks for Generator Testing to our clients. The generators are designed to provide power to faculties at times of emergency or power cuts. The factories, commercial buildings, offices, schools, colleges, malls, etc., keep backup power sources in form of generators to assure the regular supply of power and prevent hindrance. If properly maintained, gen sets will continue to get into action on a moment’s notice during an emergency. In the generator maintenance plan, load bank testing is important to assure it is completely reliable and operational. The load banks for generator testing is available here. This test is performed to check the performance of generator engine.
This device places an artificial load on the generator in order to bring its engine to desired operating temperature as well as pressure level. The generators that are only used for the emergency purpose and are no exposed to frequently carrying heavy loads, must be tested by load banks.
Motor Starting Resistor
Application rating | 4600 HP/5000 HP |
Type of winding | Series |
ARM.Voltage (motor) | 430 Volts |
Usage | Electrical industry |
Precisely manufactured in accordance with the organizational guidelines, our range of Starting Resistor is largely demanded by our clients. Available as per their requirements, our range also meets international quality standards.
Product Features:
Highly reliable
Durable standards
Robust construction
Rotor Current at full load
Technology: Thick Film
Operating Temperature: C
Rotor volts at standstill
Duty rating
Starting Torque in percentage of full load torque
Type of enclosure (Protection Class as per IS-12063)
Temperature rise allowed
No. of steps, sections and its resistance values per phase
Whether terminals should be brought down at one place
Details of atmospheric conditions at site
We deals in Gulf Countries like Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates and Middle East Countrie.
NGT Loading Resistor
Minimum Order Quantity | 1 Unit |
Brand | National Resistors |
Resistor Value | Customised |
Current | 1A - 1000A |
Generator Voltage | 415 V- 33 KV |
Material | SS 304,SS 430,SS 410,Cast iron,Fe-Cr-Al (SS-406) |
Condition | Refurbished |
Shape | Customised |
We have been offering the matchless collection of NGT+ Loading Resistor that eradicates varied problems of transitory over, lower voltages, inverse flash, inadequate current flow, and varied other major damages. Our high efficacy resistors For Transformers are designed from high-grade metal strips to avert the failure as well as short-circuit. Our collection is designed to enhance the life and efficacy of the transformers along with ensuring the reliability of electrical systems. With high durability, efficacy, and performance, our collection ensures to protect the Transformers from any kind of burning and damage. We have been offering electrical grade S.S. designed resistors to ensure to keep the resistant value same, even at high temperatures.
Features:
- Aluminum enclosure instead of MS
- Cable gland
- Earth fault leakage Relay
- Hot dip Galvanized enclosures
- Neutral Grounding Transformer/Excitation Transformer
- Potential transformers
- Safety Screen for enclosures
- Stainless steel hardware
- Standoff insulators
- Supporting Pedestal structures
- Termination kit
Starting Resistor For Slippering Motors
Resistive Values | 1ohm to 200 ohm |
Dielectric Strength | 2.5 kV AC / 1 min |
Operating Voltage | 1000 VAC / 1100 VDC |
Usage | Electrical industry |
Precisely manufactured in accordance with the organizational guidelines, our range of Starting Resistor for Slippering Motors is largely demanded by our clients. Available as per their requirements, our range also meets international quality standards. In addition to this, clients can avail the offered range from us at cost-effective prices.
Furthermore, our products are known for the below mentioned feature:
Highly reliable
Durable standards
Robust construction
Rotor Current at full load
Technology: Thick Film
Operating Temperature: C
Rotor volts at standstill
Duty rating
Starting Torque in percentage of full load Torque
Material of Resistor
Type of enclosure (Protection Class as per IS-12063)
Temperature rise allowed
No. of steps, sections and its resistance values per phase
Whether terminals should be brought down at one place
Details of atmospheric conditions at site
We deals in Gulf Countries like Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates and Middle East Countrie.
Discharge Resistors
Material | Stainless Steel |
Usage/Application | Industrial |
Weight | 250 kg Approx |
Voltage | 280KV |
Usage | Electrical industry |
Power Source | Electric |
Discharge Resistors
Material | Stainless Steel |
Usage/Application | Industrial |
Weight | 250 kg Approx |
System Rated Voltage | 280KV |
Usage | Electrical industry |
Power Source | Electric |
Isolator Panel
Body Material | Galvanized Aluminium |
Heat Insulation | 0.0856 W/(mK) |
IP Rating | IP55 |
Phase | Single Phase |
Weight Capacity | 650 kg/m3 |
Isolator Panel is specialized in fabricating resistors and panels. Isolation panels, as the name suggests, gives isolated power service as well as protection to critical areas, such as operating rooms in the hospital. It is composed of the transformer, primary and brand circuit breakers, reference ground bus, and isolation monitor distribute power to electric systems installed in operating rooms and isolated power systems.
The isolation monitors warn in case of faults and reduce downtime. It triggers the inbuilt alarm. Install isolation panels in your healthcare centers to keep running the systems safely. To buy such panel, you can contact us by calling us or sending an inquiry via email. The professionals will address your inquiry and provide the right solution. Even you can consult with them for finding the right panel to suit your specific application.
Loading Resistor
Loading Resistor is designed for safe dissipation of maximum output of the power converter, which is in a full load test condition. A load resistor is necessary in testing power converter and other devices under a power load condition, to maintain accuracy and thermal stability in the entire test sequence. High wattage loading resistors offer best power supply solution for manufacturers involved in product life testing and functional testing. The loading resistors are large and bulky but advantageous as it can be easily mounted and wired in different combinations. These resistors should be carefully chosen depending on their non-inductive properties.
Features:
- Longer service life
- Maintenance free
- Competitive price
Neutral Isolator Panel
Phase | Single |
IP Rating | IP 55 |
Material | Aluminium |
Weight Capacity | 650 kg/m3 |
Heat Insulation | 0.0856 W/(mK) |
Keeping in mind the diverse requirements of our customers, we are engaged in offering wide range of Neutral Isolator Panels (NIS Panel) Our product is manufactured in recommended specifications using latest techniques. Customers like our product for their reliability and high grade quality. Moreover, the offered product is tested to ensure their correct delivery to the clients.
Electrical Isolators
Mounting Type | Vertical |
Type | Fixed Resistor |
Resistance | 0.33-1 K |
Usage | Electrical industry |
Supported by our highly qualified and skilled professionals, we have been able to offer our esteemed clients a quality approved range of Electrical Isolators. We execute our manufacturing process by following organization set quality parameters also abide by fair and transparent business policies. Because of this, our products meet with exact demands of our clients.
Feature:
Smooth operations
Low maintenance cost
User friendly
High efficiency
Durability
Single pole and three pole
On load and off load
Motorized and manual mode of operation
Can be mounted on walls, structures or in switchboards
High operating reliability
Simple maintenance and inspection.
Neutral Side Cubicles
Phase | Three Phase |
Voltage | 33 kV |
Number of Wires | 5 |
Power | 45 W |
Neutral Side Cubicles and generator outlet are generally used for the connection of power terminals of the generators to other systems. Neutral side cubicles are also known as Main Terminal Boxes-MTBs. These cubicles have the required protective and measuring devices. A connection point is provided on the cubicle outlet for the encapsulated conductors or power cables. Depending on the size and construction of the genset, the number of cubicles varies. One design includes a single common cubicle for neutral and outlet point. The second design has two separate cubicles, one for the outlet devices and second for the generator neutral point.
Neutral side cubicles are generally equipped with the voltage & current measuring, protection transformers, RC elements and surge arresters. The said RC elements play the role of over-voltage protector. These are custom designed and made by us, hence each solution is individual and personalized, ensuring more efficiency.
Neutral Side Cubicles
Phase | Three Phase |
Voltage | 33 kV |
Number of Wires | 5 |
Power | 45 W |
Neutral Side Cubicles and generator outlet are generally used for the connection of power terminals of the generators to other systems. Neutral side cubicles are also known as Main Terminal Boxes-MTBs. These cubicles have the required protective and measuring devices. A connection point is provided on the cubicle outlet for the encapsulated conductors or power cables. Depending on the size and construction of the genset, the number of cubicles varies. One design includes a single common cubicle for neutral and outlet point. The second design has two separate cubicles, one for the outlet devices and second for the generator neutral point.
Neutral side cubicles are generally equipped with the voltage & current measuring, protection transformers, RC elements and surge arresters. The said RC elements play the role of over-voltage protector. These are custom designed and made by us, hence each solution is individual and personalized, ensuring more efficiency.