Our product range includes a wide range of ngr with monitoring (failsafe) relay for mines, ngr with vc panel, ngr with pulsating circuit, 22 kv ngr, 33kv neutral grounding resistor and punched patti stainless steel grid type ngr.
NGR with Monitoring (Failsafe) Relay for Mines
Product Price: Rs 2.5 Lakh / PieceGet Best Price
Minimum Order Quantity: 1 Piece
Product Details:
Shape
Other (As per customer Requirement)
Usage/Application
Neutral Grounding of Generators & Parallel Generators
Brand
National Resistors
Part Number
NA
Mounting type
Through Hole
Wattage
As per customer requirement/as per calculations
Surface Treatment
Soft & Anneleaed
In outdoor distribution station there are many possibilities of damage to the neutral grounding connections due to various environmental effects causing open circuit or burning of NGR. This is a very dangerous continuity i.e. totally floating type. This may also result in failure of earth-leakage protection operating through neutral CT as the leakage current may not be able to flow through open circuit of neutral grounding connection.To prevent this type of failure, Fail Safe Relays must be installed. The fail safe relay will continuously monitor the continuity of NGR and neutral grounding connections and will trip the feeder circuit breaker as and when any open circuit occurs in neutral grounding connection or in NGR. The fail safe relay will ensure fail safe operation of neutral grounding system.This Type of system is generally used in Mines & Oil IndustryFor Mines, as per DGMS Guidelines, for MV System (3.3kV, 6.6kV & 11kV) Fault current is restricted to 50A and for LT system (415V & 230V) fault current is resyricted to 0.750mA.
Additional Information:
Production Capacity: 25 Nos./Month
Delivery Time: 8 weeks from Manufacturing clearance
Get Best QuoteRequest A Callback
NGR with VC Panel
Product Price: Rs 3.5 Lakh / PieceGet Best Price
Product Details:
Resistance
As per customer requirement/as per calculations
Brand
National Resistors
Part Number
NA
Mounting type
Through Hole
Usage/Application
Neutral Grounding of Generators & Parallel Generators
NGR & VC PANEL normally consist of two separate cubicles attached to each other. The Resistance cubicle consists of number of Resistance Banks (Tiers) mounted one on top other and supported on HT Insulators. The enclosure is fitted with covers, provided with louvers and wiremesh. A Space Heater is provided to prevent condensation of moisture.This Type of system is used for Parallel operating Generators in which all VC's are interlocked with each other and at a time only one VC is connected to NGR. In such system one comman NGR is used for multiple Generators. The NIS Cubicle houses the Isolating Switch (Vacuum Contactor) and CTs, as desired.LT Terminal Box for housing Thermostat and MCB, ON / OFF indicating lamps & LT terminals of Isolator & CTs etc. are provided in the NIS Cubicle.
Get Best QuoteRequest A Callback
NGR with Pulsating circuit
Product Price: Rs 2 Lakh / PieceGet Best Price
Product Details:
Resistance
As per customer requirement/as per calculations
Brand
National Resistors
Part Number
NA
Mounting type
Through Hole
Usage/Application
Neutral Grounding of LV System
Where continuity of service is a high priority, high-resistance grounding can add the safety of a grounded system while minimizing the risk of service interruptions due to grounds. The concept is a simple one: provide a path for ground current via a resistance that limits the current magnitude, and monitor to determine when an abnormal condition exists. This provides for maximum continuity of service, because no tripping occurs for the resistance limited ground fault.The ground current path is provided at the point where the service begins, by placing resistance in the connection from system neutral to ground. Control equipment continuously measures ground current; a relay detects when the current exceeds a predetermined level. An alarm alerts building personnel that a ground exists. The system has built-in fault tracing means to assist in finding the source of the ground. An integral transformer provides control power from the primary source.The pulser circuit offers a convenient means to locate the faulted feeder and trace the fault to its origin. The pulser is available any time a fault has been detected. The pulse intervals are controlled by an adjustable recycle timer. The “pulse” light flashes on and off, corresponding to the on-off cyclesof the pulser contactor. The pulser contactor switches a bank of resistors on and off, thus allowing a momentary increase in the ground current (approximately a 5 A current pulse above the ground current).The current pulses can be noted with a clamp-on ammeter when the ammeter is placed around the cables or conduit feeding the fault. The operator tests each conduit or set of cables until thepulsing current is noted. By moving the ammeter along the conduit, or checking the conduit periodically along its length, the fault can be traced to its origin. The fault may be located at the point where the pulsing current drops off or stops.
Get Best QuoteRequest A Callback
22 KV NGR
Product Price: Rs 2.5 Lakh / PieceGet Best Price
Product Details:
Resistance
As per customer requirement/as per calculations
Brand
National Resistors
Part Number
- NA
Mounting type
Through Hole
Wattage
As per customer requirement/as per calculations
Shape
Other (Rod. Sheet)
Neutral Grounding Resistors (NGRs) are used to limit the fault current and ensure safety of equipment and personnel in industrial systems.Neutral Grounding Resistor systems can be inserted between the neutral and ground in a power system to provide ground fault protection through resistance. The fundamental purpose of a Neutral Grounding Resistor (NGR) is to limit ground fault currents to safe levels so that sensitive and selective earth fault protection relay can take place and all the electrical equipment in a power system is protected. Neutral Grounding Resistors are also commonly referred to as Neutral Earthing Resistors and Earth Fault Protection Resistors.Technical Specifications• Operation Voltage : 22 kV line to line system• Rated Current : Up to 5000 A• Ambient Temperature : Up to 50 C (For higher ambient temperature, consult factory)• Resistance Alloy : Stainless-steel (AISI-304) , AISI -430 FeCrAl , Cu-Ni , Ni-Cr , Cast Iron• Protection Degree : IP 33 (outdoor) and others on demand• Standards : IEEE 32, IEC 60529
Get Best QuoteRequest A Callback
33KV Neutral Grounding Resistor
Product Price: Rs 3.5 Lakh / PieceGet Best Price
Product Details:
Rated frequency
- As per customer requirement/as per calculations
Shape
Customized
Usage/Application
Neutral Grounding of Transformer/Generator
Mounting type
Through Hole
Surface Treatment
B2B
Ambient Temperature
- As per customer requirement/as per calculations
Neutral Grounding Resistors (NGRs) are used to limit the fault current and ensure safety of equipment and personnel in industrial systems.Neutral Grounding Resistor systems can be inserted between the neutral and ground in a power system to provide ground fault protection through resistance. The fundamental purpose of a Neutral Grounding Resistor (NGR) is to limit ground fault currents to safe levels so that sensitive and selective earth fault protection relay can take place and all the electrical equipment in a power system is protected. Neutral Grounding Resistors are also commonly referred to as Neutral Earthing Resistors and Earth Fault Protection Resistors.Technical Specifications• Operation Voltage : 33 kV line to line system• Rated Current : Up to 2000 A• Ambient Temperature : Up to 50 C (For higher ambient temperature, consult factory)• Resistance Alloy : Stainless-steel (AISI-304) , AISI -430 FeCrAl , Cu-Ni , Ni-Cr , Cast Iron• Protection Degree : IP 33 (outdoor) and others on demand• Standards : IEEE 32, IEC 60529
Get Best QuoteRequest A Callback
Punched Patti Stainless Steel Grid Type NGR
Product Price: Rs 2 Lakh / PieceGet Best Price
Product Details:
Part Number
NA
Mounting type
Through Hole
Usage/Application
Neutral Grounding of Transformer/Generator
Wattage
As per customer requirement/as per calculations
Surface Treatment
B2B
Resistance
As per customer requirement/as per calculations
Brand
National Resistors
NGR Element Material -Patti Grid is one of the Type of construction of Resistor Element. This Type of Resistor elements are used in generally in NGR which is having High current rating i.e. 800A-1500A Advantages of This Type Elements,1. Suitable for Higher currents & Large time rating2. Cooling is achieved better in this type of construction. Resistor Element - AISI-304, AISI -430, Fe-Cr-Al (AISI-406) NGR Enclsoure Material-Enclosure will be provided in MS (CRCA), Aluminium, Unpainted Stainless Steel (AISI-304/316), painted Stainless Steel (AISI-304/316), Hot Dip Galvanised, Normal Galvanising as per customer requirement and thciness of enclosure will be 1.5mm -3 mm as per customer requirement
Get Best QuoteRequest A Callback
NGR & NIS Panel
Product Price: Rs 3 Lakh / PieceGet Best Price
Minimum Order Quantity: 1 Piece
Product Details:
Usage/Application
Neutral Ground
Resistance
As per customer requirement/as per calculations
Surface Treatment
Soft & Anneleaed
Brand
Resistors
Mounting type
Through Hole
NGR & NIS PANEL normally consist of two separate cubicles attached to each other. The Resistance cubicle consists of number of Resistance Banks (Tiers) mounted one on top other and supported on HT Insulators. The enclosure is fitted with covers, provided with louvers and wiremesh. A Space Heater is provided to prevent condensation of moisture.A Single Pole Isolator is provided in the Neutral Circuit and the other end is connected to the NGR. The HT Bushings, to connect the NGR Terminals are mounted on the partition wall of the NGR & NIS Cubicles.LT Terminal Box for housing Thermostat and MCB, ON / OFF indicating lamps & LT terminals of Isolator & CTs etc. are provided in the NIS Cubicle.
Additional Information:
Production Capacity: 25 Nos./Month
Delivery Time: 4 week
Get Best QuoteRequest A Callback
Punched Stainless Steel Grid Type NGR
Product Price: Rs 1.5 Lakh / UnitGet Best Price
Product Details:
Resistance
50ohm
Resistance Tolerance
5%
Rated Power
20kv
Temperature Coefficient
500PPM
Operating Temperature
20 ~ +40
Standard
IEEE32
NGR Element Material -Punched Stainless Steel Grid is one of the Type of construction of Resistor Element. This Type of Resistor elements are used in generally in Oil Industry, BHEL, NTPC, Adani, EIL etc Advantages of This Type Elements,1. Better cooling due to larg surface area2. Element to Elment Bolted Connections3. Easy Replacement of Elements4. Suitable for continuous rating applications Resistor Element - Material used for this type of construction are AISI-304, AISI-430 NGR Enclsoure Material-Enclosure will be provided in MS (CRCA), Aluminium, Unpainted Stainless Steel (AISI-304/316), painted Stainless Steel (AISI-304/316), Hot Dip Galvanised, Normal Galvanising as per customer requirement and thciness of enclosure will be 1.5mm -3 mm as per customer requirement.
Get Best QuoteRequest A Callback
Wire Grid Type NGR
Product Price: Rs 80,000 / PieceGet Best Price
Product Details:
Full load current
10%
Material
Stainless Steel
Type
Resistor
Temperature
375 degree celsius
We provide an exclusive range of Wire Grid Type NGR.
Features :
Continuous Rating: It is normally 10 % of full load current for healthy system neutral grounding resistor to be designed for continuous rating of 5 % to 10 % of full load current (if required)
The material of Resistance Element: We offer resistor elements made from any stainless steel or FeCrAl or Cu-Ni or Ni-Cr or any other resistance material as per requirement. Normally formed stainless steel element is best and economical for NGRS
Temperature Rise Allowed: Normally Temperature rise is restricted to 375 deg.c. above ambient temperature as per BS-587. It can be 760 deg.c. as per IEEE-32. It can be offered of any other temperature rise as per customer's requirement
Construction: NGR includes resistor assembly, plus required insulators, internal connections and hardware etc
Cabling / Termination: Suitable arrangement and clearance are provided for termination of cable, flats or bus duct as per requirement with undrilled removable gland plate
Get Best QuoteRequest A Callback
Wire Wound Type Neutral Grounding Resistor
Product Price: Rs 1 Lakh / UnitGet Best Price
Product Details:
System Voltage
1.732
Temperature
375 deg.c
Full load current
5% and 10%
Material
Stainless steel
NGR Element Material -Wire wound Grid is one of the Type of construction of Resistor Element. This Type of Resistor elements are used in generally in NGR which is having very small current rating i.e. upto 5A Advantages of This Type Elements,1. Suitable for smaller currents2. Constant Resistance Resistor Element - Ni-Cr (80-20%), AISI-304, Fe-Cr-Al (AISI-406), Cu-Ni NGR Enclsoure Material-Enclosure will be provided in MS (CRCA), Aluminium, Unpainted Stainless Steel (AISI-304/316), painted Stainless Steel (AISI-304/316), Hot Dip Galvanised, Normal Galvanising as per customer requirement and thciness of enclosure will be 1.5mm -3 mm as per customer requirement
Get Best QuoteRequest A Callback
Cast Iron Grid Type NGR
Product Price: Rs 3 Lakh / UnitGet Best Price
Product Details:
Temperature coefficient of resistance
0.05% per oC
Type
Resistor
Usage
Electrical industry
Material
Cast Iron
NGR Element Material -Cast Iron Grid is one of the Type of construction of Resistor Element. This Type of Resistor elements are used in generally in NGR which is having very Hight current rating i.e. 2000-3000A Advantages of This Type Elements,1. Suitable for higher currents2. Resistor element is a continues without breakage Resistor Element - Cast Iron NGR Enclsoure Material-Enclosure will be provided in MS (CRCA), Aluminium, Unpainted Stainless Steel (AISI-304/316), painted Stainless Steel (AISI-304/316), Hot Dip Galvanised, Normal Galvanising as per customer requirement and thciness of enclosure will be 1.5mm -3 mm as per customer requirement
Get Best QuoteRequest A Callback
Formed Stainless Steel Grid Type NGR
Product Price: Rs 1.2 Lakh / UnitGet Best Price
Product Details:
Application
Electrical indusrtry
Thickness
0.4-1.0mm
Zinc coating
60-140g/sq.m
Temperature coefficient of resistance
0.15% / c and 0.094%/ c
NGR Element Material -Formed Stainless Steel Grid is one of the Type of construction of Resistor Element. This Type of Resistor elements are used in generally in cement Indusrty Industry and High current application Advantages of This Type Elements,1. High Mechnanical stength 2. Good ability to absorb mechnical vibrations3. Resistor element to element welded connections4. econiomical construction Resistor Element - Material used for this type of construction are AISI-304, AISI-410 & AISI -406 NGR Enclsoure Material-Enclosure will be provided in MS (CRCA), Aluminium, Unpainted Stainless Steel (AISI-304/316), painted Stainless Steel (AISI-304/316), Hot Dip Galvanised, Normal Galvanising as per customer requirement and thciness of enclosure will be 1.5mm -3 mm as per customer requirement